Home › Home Remodeling Glossary › R-Value
Energy Efficiency term
R-Value
Definition: R-value measures how well an insulation material resists heat flow, and a higher R-value means greater insulating power.
What is R-value?
ENERGY STAR describes R-value as a measure of insulation’s ability to resist heat traveling through it: the higher the R-value, the better the thermal performance.
Windows are rated the other way. The U.S. Department of Energy’s Building America window guide explains that windows use U-factor, while R-value is used for walls, floors and roofs. To compare them, divide 1 by the U-factor, so a 0.25 U-factor equals an R-value of 4.
Why it matters
Most of Maryland, including the Baltimore region, falls in Department of Energy climate zone 4. For that zone, ENERGY STAR recommends bringing an uninsulated attic to R-60, or adding to R-49 if the attic already has 3 to 4 inches of insulation. Air sealing the attic floor first matters as much as the insulation itself, because insulation slows heat but does not stop air leaks.
ENERGY STAR’s retrofit table, based on the 2021 International Energy Conservation Code, goes beyond the attic. For climate zones 4A and 4B it recommends R19 for floors, and it gives specific guidance for walls and basements, which matters most when siding is off or a basement is being finished.
When siding comes off
ENERGY STAR advises using the opening whenever exterior siding is removed:
- Uninsulated wood-frame wall: drill holes in the sheathing and blow insulation into the empty cavity before the new siding goes on, and in zones 4 to 8 add R5 to R10 insulative wall sheathing beneath it.
- Insulated 2×4 wood-frame wall: in zones 4 to 8, add R10 insulative wall sheathing beneath the new siding.
ENERGY STAR notes this guidance is based on Table R402.1.3 of the 2021 IECC residential provisions, and points readers to the code itself for more detailed guidance.
Basements and crawlspaces
For zones 4A and 4B, ENERGY STAR recommends R10 insulative wall sheathing or an R13 batt on basement or crawlspace walls. In zones 4C and 5 to 8 the recommendation rises to R15 sheathing or an R19 batt, which shows how the targets climb in colder climates.
Insulation on permitted projects
In Carroll County, a new home or addition goes through an insulation inspection, and the permit application must include a current Residential Energy Compliance Form. The county has adopted the 2021 International Energy Conservation Code as amended by the Maryland Building Performance Standards.
Learn more
These pages cover projects where insulation levels are set and checked.
Related Certified Home Remodelers services
Frequently asked questions
Is a higher R-value better?
For insulation, yes. ENERGY STAR says the higher the R-value, the better the thermal performance.
How do I compare a window’s U-factor with an R-value?
Divide 1 by the U-factor. The DOE Building America window guide gives the example that a 0.25 U-factor equals an R-value of 4.
What R-value does ENERGY STAR suggest for floors in zone 4?
R19 for floors in climate zones 4A and 4B, based on the 2021 International Energy Conservation Code.
Is the ENERGY STAR table meant for new homes?
No. ENERGY STAR presents it as recommended insulation levels for retrofitting existing wood-framed buildings. New homes and additions in Carroll County follow the adopted energy code through the permit process.
Sources
- ENERGY STAR: Recommended Home Insulation R-Values
- US DOE: Consumer Guide to Energy Efficient Windows
Planning a project in Carroll County?
Ask about your remodel, addition, roof or siding project: Contact Certified Home Remodelers.